Log in
EN
Start trial
How it worksRemote accessBenefitsMonitorAI integrationTimelineChartsProjectSupported loggersNewsPricingFAQLog in

Supported loggers › ABB APP-Control Server

APP-Control Server

The ABB APP-Control Server has a built-in KNX bus connection, so it works as the KNXSENSE logger without a separate KNX/IP gateway.

The previous generation was known as Busch-ControlTouch.

ABB APP-Control Server as the KNXSENSE logger
How it works

How the logger works.

The KNXSENSE logger is installed on the device as separate software. It has no effect on anything else the device does. Logic, visualisation, interfaces and scripts keep running as normal.

The logger only reads bus traffic and never writes to the bus. The connection is established outbound from the site, so no open ports and no static IP address are needed. The logger also works behind a shared carrier IP address.

Logging requires the APP-Control Server to be powered on continuously and the site to have an internet connection.

Specifications
Manufacturer
ABB
Remote ETS access
Via KNXSENSE
Manufacturer’s product page
new.abb.com →

KNXSENSE-compatible models

  • CT/S2.1
  • CT/S2.11
  • 6136/APP-500
  • 6136/APP
1.0  main lineroutednot routed1.1.01.2.01.3.0loggerLine 1.1Line 1.2Line 1.3KNXSENSE400-day recording400 days agotoday
Logging coverage

How telegrams reach the recording.

The APP-Control Server is connected directly to the KNX bus, so it sees the telegram traffic on its own line and everything the line couplers route onto that line from the other lines.

KNXSENSE compares the addresses it sees against your ETS project and tells you straight away which lines and devices are in the recording and which are missing.

KNX telegram logging

KNX bus monitoring in your browser.

Jokainen sanoma, jonka APP-Control Server näkee väylällä, tallentuu ympäri vuorokauden millisekunnin tarkkuudella tietoturvallisille palvelimillemme , myös silloin, kun et ole paikalla.

Telegram-level history reaches 400 days back on a rolling window. You can browse it in your browser, on any device, without the ETS software.

TimeSource addressSource nameDestination addressDestination nameValue
09:14:02.1811.2.31Elsner Suntracer KNX sl0/5/9Rain detectionno rain
09:14:02.4571.1.15Elsner Intra-Sewi KNX TH-L1/1/54Measured room temperature: Bathroom24.6°C
09:14:03.5673.1.13MDT SCN-RT1GS.011/1/61Measured temperature: Plant room18.9°C
09:14:04.6771.2.31Elsner Suntracer KNX sl0/5/6Wind speed4.2m/s
09:14:05.0882.1.40MDT SCN-RT1GS.011/1/72Measured temperature: Guest house19.2°C
09:14:05.1621.1.30Steinel True Presence KNX0/7/4Presence: home officedetected
09:14:05.2361.1.28MDT Glass Push Button II0/6/2Scene: evening lighting2
09:14:05.6471.1.43Theben DM 4-2 T KNX0/2/30Home office: desk lamp VALUE90%
09:14:05.7101.1.44MDT Shutter Actuator JAL-0810.023/1/12Bedroom: venetian blind POSITION100%
09:14:05.8291.1.28MDT Glass Push Button II3/2/4Blinds: south facade POSITION65%
09:14:06.5181.1.34ABB SA/S 8.16.5.2 Switch Actuator0/1/14Kitchen: worktop lighting CONTROLon
09:14:07.2071.1.5ABB DALI-Gateway DG/S 8.10/2/5Living room: general lighting VALUE72%
Remote KNX access

ETS tunnelling through KNXSENSE.

You open the connection from the interface, and from there you program the site in ETS as if you were on site.

Logging reserves one ETS tunnel slot and holds on to it. The remaining slots stay free for ETS, so remote access works alongside logging.

Remote access is included in the KNXSENSE monthly fee. No separate portal, licence or port forwarding is needed.

Setup

Setting up the APP-Control Server as a KNX logger.

KNXSENSE’s setup assistant walks you through the right settings step by step.

The whole setup takes only a few minutes.

  1. Import your ETS projectNames and structure from the project into KNXSENSE
  2. Install the loggerGuided install on the device
  3. Logging is runningThe first telegram from the site’s bus confirms the connection

Setup is a one-off job. When updates to the logger are released, they are installed on the device automatically. Updating requires no action from you and no visit to the site.